fix(proton): harden generated protobuf decoders
Reject malformed varints, out-of-bounds fields, and invalid groups before they escape their parent frame. Aggregate unknown-field metadata and decode signed int32 values while preserving SnowLuma's existing outbound encoding bytes.
This commit is contained in:
7 files changed
+311
-32
No files matched your search
@@ -95,6 +95,74 @@ function __zigZagEncode64(value) {
|
||||
function __zigZagDecode64(value) {
|
||||
return BigInt.asIntN(64, (value >> 1n) ^ -(value & 1n));
|
||||
}
|
||||
function __readVarint32(data, offset, end) {
|
||||
let value = 0;
|
||||
for (let i = 0; i < 5; i++) {
|
||||
if (offset >= end) throw new Error('protobuf truncated uint32 varint');
|
||||
const byte = data[offset++];
|
||||
if (i === 4 && (byte & 0xf0) !== 0) throw new Error('protobuf uint32 varint overflow');
|
||||
value += (byte & 0x7f) * (2 ** (i * 7));
|
||||
if ((byte & 0x80) === 0) return [value >>> 0, offset];
|
||||
}
|
||||
throw new Error('protobuf uint32 varint overflow');
|
||||
}
|
||||
function __readVarint64(data, offset, end) {
|
||||
let value = 0n;
|
||||
for (let i = 0; i < 10; i++) {
|
||||
if (offset >= end) throw new Error('protobuf truncated uint64 varint');
|
||||
const byte = data[offset++];
|
||||
if (i === 9 && byte > 1) throw new Error('protobuf uint64 varint overflow');
|
||||
value |= BigInt(byte & 0x7f) << BigInt(i * 7);
|
||||
if ((byte & 0x80) === 0) return [value, offset];
|
||||
}
|
||||
throw new Error('protobuf uint64 varint overflow');
|
||||
}
|
||||
function __skipVarint(data, offset, end) {
|
||||
for (let i = 0; i < 10; i++) {
|
||||
if (offset >= end) throw new Error('protobuf truncated varint');
|
||||
const byte = data[offset++];
|
||||
if (i === 9 && byte > 1) throw new Error('protobuf varint overflow');
|
||||
if ((byte & 0x80) === 0) return offset;
|
||||
}
|
||||
throw new Error('protobuf varint overflow');
|
||||
}
|
||||
function __checkedEnd(offset, length, end) {
|
||||
if (length > end - offset) throw new Error('protobuf length-delimited field exceeds parent bounds');
|
||||
return offset + length;
|
||||
}
|
||||
function __skipUnknownField(data, offset, end, wireType, fieldNumber, depth = 0) {
|
||||
if (depth > 64) throw new Error('protobuf group nesting exceeds 64');
|
||||
if (wireType === 0) return __skipVarint(data, offset, end);
|
||||
if (wireType === 1) {
|
||||
if (end - offset < 8) throw new Error('protobuf truncated fixed64 field');
|
||||
return offset + 8;
|
||||
}
|
||||
if (wireType === 2) {
|
||||
const [length, next] = __readVarint32(data, offset, end);
|
||||
return __checkedEnd(next, length, end);
|
||||
}
|
||||
if (wireType === 3) {
|
||||
while (offset < end) {
|
||||
const [tag, next] = __readVarint32(data, offset, end);
|
||||
offset = next;
|
||||
const nestedField = tag >>> 3;
|
||||
const nestedWire = tag & 0x7;
|
||||
if (nestedField === 0) throw new Error('protobuf field number 0 is invalid');
|
||||
if (nestedWire === 4) {
|
||||
if (nestedField !== fieldNumber) throw new Error('protobuf mismatched end-group tag');
|
||||
return offset;
|
||||
}
|
||||
offset = __skipUnknownField(data, offset, end, nestedWire, nestedField, depth + 1);
|
||||
}
|
||||
throw new Error('protobuf unterminated group');
|
||||
}
|
||||
if (wireType === 4) throw new Error('protobuf unexpected end-group tag');
|
||||
if (wireType === 5) {
|
||||
if (end - offset < 4) throw new Error('protobuf truncated fixed32 field');
|
||||
return offset + 4;
|
||||
}
|
||||
throw new Error('protobuf invalid wire type ' + wireType);
|
||||
}
|
||||
function __writeFloat32(buf, offset, value) {
|
||||
__scratch.setFloat32(0, value, true);
|
||||
buf[offset++] = __scratch.getUint8(0);
|
||||
|
||||
Reference in new issue